Section: Visu

SEC Visu                                          //optional: yes, modifier: [UPDATE]
    Toplevel_Tab;                                 //optional: yes, type: bool
    Embedded := [%PAGE_VISU%, <visu1>,...];       //optional: yes, type: VisuList
    Embedded_Proxy := [%PAGE_VISU%, <visu1>,...]; //optional: yes, type: VisuList
    Page =: [<visu1>, <visu2>,...];               //optional: yes, type: VisuList

    SEC DefaultEmbeddings                         //optional: yes
            SEC Embedding : <visu identifier>         //optional: yes, modifier: [HIDE, UPDATE]
                    VisuName := <visu name>;                    //optional: no, type: literal
                    Target := <target name>;                    //optional: yes, type: literal
                    ProxyVisuName := <visu name>;               //optional: yes, type: literal
                    LinkId := <linkID>;                         //optional: yes, type: literal
            END_SEC
    END_SEC

    SEC Toplevel_Tab_Hotkey                      //optional: yes
            Hotkey := <keycode>;                        //optional: no, type: literal
            Modifiers := <modifier>;                    //optional: yes, modifier: [SHIFT, CONTROL, ALT]
    END_SEC

END_SEC

Details regarding the syntax of definition types are described in the section Module Declaration.

. Specification:
  • Toplevel_Tab defines if the check box Create top-level tab in the HMI editor is activated or deactivated by default.

  • Page defines a list of available visualization objects for the module.

  • Embedded defines a list of available visualization objects of the submodule that will be embedded in other visualization screens.

    Using the placeholder %PAGE_VISU% instead of the visualization name allows that generated visualization screens optionally can be embedded in other screens.

  • Embedded_Proxy defines a list of available visualization objects of the module. The list is only used if a decoupled module is inserted in a decoupled slot and if it is not created below the controller of its father module instance (as a proxy).

  • For modules, which import another module, the placeholder %NONE% can be used instead of the visualization name. This effects that the imported visualizations are hidden. This approach is possible for the list of visualization screens as well as for embedded (proxy-)visualization screens.

  • Section: DefaultEmbeddings: This section serves for the specification of default embeddings, which then will appear as a pre-configuration on the HMI tab of a submodule (similar to section "Default_Allocation", see Section: Slots). The desired default embeddings are to be described in subsections Embedding.

    Requirement: The specified visualization object and the proxy must be available in the list of possible embeddings for the module (see above: Embedded and Embedded_Proxy).

  • Section: Toplevel_Tab_Hotkey: This section defines a hotkey as default setting for the toplevel page. Keyboard shortcuts must not be used more than once. This setting can be adjusted in the module editor on the HMI tab.

Example 18. Example
SEC Visu
        Toplevel_Tab ;
        Page := [VISU_CNC_Machine_1, VISU_CNC_Machine_2];
        Embedded := [%PAGE_VISU%];
        SEC DefaultEmbeddings
                 SEC Embedding : No1
                         VisuName := SubModule_Emb;
                         Target := '../../TopLevel_2';
                 END_SEC
                 SEC Embedding : No2
                         VisuName := SubModule_Emb_2;
                         //ProxyVisuName := SubModule_Emb_1;
                         Target := '';// leave empty for next ancestor
                 END_SEC
        END_SEC
        SEC Toplevel_Tab_Hotkey
                Hotkey := T;
                Modifiers := SHIFT | CONTROL;
        END_SEC
END_SEC


The visualization name is the name of the respective visualization object (not case sensitive). The visualization object must be in the same hierarchical level as the module function block.

. Rules for the interface of visualization objects:
  • All visualization objects and embedded visualization objects can have a VAR_IN_OUT variable with the name inst, which can be of the type of the module function block or of a base class. The variable name is not case sensitive.

    VAR_IN_OUT

      inst : <MODULE_FB> ;

    END_VAR

    As an alternative to the option described here with VAR_IN_OUT, a VAR_INPUT variable can also be used. This variable must meet the following requirements:

    • Name: inst

    • Type: Interface which the module function block implements

  • Embedded visualization objects can have two additional variables (the variable names are not case sensitive):

    VAR_INPUT

    paVisuFB : POINTER TO POINTER TO AC_Visu_Base ;

    iOwnFrameIndex : INT ;

    END_VAR

    These variables must be defined together; it is not allowed to define one without the other. These two variables give embedded visualizations the ability to switch the central frame in the top-level visualization. paVisuFB is an array of pointers on AC_Visu_Base instances. Use the global visualization variable CURRENTCLIENTID to access the correct instance of the current client. The frame switching is performed by an ST action of the form:

    paVisuFB[CURRENTCLIENTID]^.uiFrameIdx := iOwnFrameIndex ;

    iOwnFrameIndex is the index that the visualization image of the own module has in this toplevel frame. (If the own module does not define a visualization image this index is -1.)

  • Apart from the variables mentioned above, no other VAR_INPUT, VAR_OUTPUT or VAR_INOUT variables are allowed.

  • The AC_Visu_Base instances provide the additional function GetModuleFrameIndex. This function returns the index of the visualization screen (if present) in the top-level visualization for a module instance (see IModule in AC_Module_Base.library). With this function, you can jump to any visualization screen in the module instance tree. To also enable the navigation within the code of a module, the environment of the module (see IModule in AC_Module_Base.library) possesses a member, Environment.visus, which corresponds to the above-mentioned paVisuFB pointer.

Tip

To be able to use the variable CURRENTCLIENTID, the library VisuGlobalClientManager (category "Intern|Visu") must be added to the project.

The first visualization will be used as the default setting.